4 commands, Commands – INFICON HLD6000 Refrigerant Leak Detector Interface Description User Manual

Page 20

Advertising
background image

20

LD Protocol

3.4

Commands

Command

Class Name

R/W Data type Description

dez

hex

0

0

Control NOP

R

NO_DATA "No operation", replies without data

1

1

Control Start

W

NO_DATA Switch from "standby" to "measure"

2

2

Control Stop

W

NO_DATA Switch from "measure" to "standby"

4

4

Control Calibration

W

NO_DATA Start calibration with ext. Testleak

5

5

Control Clear error

W

NO_DATA Clear Error or Warning

11

B

Control Calibration acknowledge

W

UINT8

1 = Continue calibration
0 = cancel calibration

128

80

Meas

Leak rate [sel. unit]

R

FLOAT

Leak rate in selected unit

129

81

Meas

Leak rate [g/a]

R

FLOAT

Leak rate in g/a

142

8E

Meas

Leak detector operation hours R

UINT32

Leak detector operation hours

147

93

Meas

Time since power on [min]

R

UINT32

Time since power on [min]

152

98

Meas

Probe operation hours [h]

R

UINT32

Probe operation hours

157

9D

Meas

Switch on counter

R

UINT16

Counts the switch on cycles
0 ... 65534

165

A5

Meas

Electronic temperature [deg. C] R

FLOAT

Mainboard Temperatur in °C

177

B1

Meas

Probe test voltage [V]

R

FLOAT

Probe test voltage

178

B2

Meas

Probe acceleration value

R

UINT16

Probe acceleration value

179

B3

Meas

IR source voltage [V]

R

FLOAT

IR source voltage

180

B4

Meas

IR source current [I]

R

FLOAT

IR source current

201

C9

Meas

3.3 V supply [V]

R

FLOAT

3.3 V supply voltage for processor

210

D2

Meas

+12 V supply [V]

R

FLOAT

+12 V Spannung in V

211

D3

Meas

-12 V supply [V]

R

FLOAT

-12 V Spannung in V

213

D5

Meas

24 V supply IO [V]

R/W FLOAT

24 V IO-Modul supply voltage [V]
write for internal use only

218

DA

Meas

+5 V supply [V]

R

FLOAT

+5 V Spannung in V

219

DB

Meas

24V power out M12 [V]

R

FLOAT

24 V out M12, Spannung in V

220

DC

Meas

Analog input IO module [V]

R/W FLOAT

Analog input voltage IO module in [V]
write for internal use only

221

DD

Meas

Analog outputs IO [V]

R

FLOAT[2]

Analog output voltage for IO module in [V].
It is possible to write an arbitrary voltage value, if the
"Analog output configuration" (command 222) of the
accordant channel is set to 2.

222

DE

Param Analog output configuration IO

module

R/W UINT8[2]

Function of analog output
Index 0: Channel 1
Index 1: Channel 2
Functions
0: 0 V fixed
1: leak rate linear (see command 225)
2: Voltage setable by command 221

225

E1

Param Analog output upper value [g/a

for 10V]

R/W FLOAT

Upper limit for the analog out at IO module (Default: 1).
The value sets the leak rate in g/a for an output voltage of
10V (Min: 10; Default: 100; Max.: 1000).