3 comparison between ascii- and ld protocol, Comparison between ascii- and ld protocol – INFICON HLD6000 Refrigerant Leak Detector Interface Description User Manual

Page 6

Advertising
background image

6

Interface Protocols

1.3

Comparison between ASCII- and LD Protocol

ASCII- and LD protocol have nearly the same functional range, but each of them
have some advantages and disadvantages:

ASCII protocol:

Advantages:

• human readable

• easy to use with simple terminal program

Disadvantages:

• No checksum, therefor lower data security

• PC/ PLC software must convert numerical values from ASCII string to binary

• Lower efficiency (for example: 8 data bytes for one float value)

LD protocol:

Advantages:

• Leak detector status always transmitted in each slave telegram

• High data security due to CRC checksum

• Binary transmission of numerical values – no conversion needed in PC/PLC

software

• High efficiency (for example: 4 Byte data bytes for one float value)

Disadvantages:

• Not human readable

• Not useable with simple terminal program

Advertising