2 the control panel, 3 the display grid – INFICON XTC/3 Thin Film Deposition Controller Software Editor Operating Manual User Manual

Page 65

Advertising
background image

4 - 3

IP

N 07

4-

45

2-

P1

A

XTC/3 Editor Operating Manual

The following data are collected from the XTC/3 for each controller:

Rate . . . . . . . . . . . . . . . . . . . . . . . . . measured rate of accumulation.

Rate Deviation . . . . . . . . . . . . . . . . calculated from the difference of the

measured rate to the rate setpoint. From the
dropdown list, one can select Rate Dev +/- 5
Å/s,+/- 10 Å/s,+/- 20 Å/s or +/- 40 Å/s

NOTE: The Dev choices from the dropdown list are for the same data but

provide different choices of scale for the Y-axis.

Power. . . . . . . . . . . . . . . . . . . . . . . . The Power, in %, of the Channel control

output.

Thickness . . . . . . . . . . . . . . . . . . . . The Thickness in kÅ of the accumulation on

the substrate.

Frequency . . . . . . . . . . . . . . . . . . . . The Frequency in Hz of the active crystal.

Crystal Life . . . . . . . . . . . . . . . . . . . The Life in % of the active crystal.

NOTE: Refer to the XTC/3 Thin Film Deposition Controller Operating Manual (IPN

074-446-P1) for a more thorough understanding of the data parameters.

4.2.2 The Control Panel

The Control Panel provides a grid and buttons to control the display and collection
of data.

4.2.3 The Display Grid

A display can be removed from the view by unchecking the checkbox located at the
top of the grid. This is shown in

Figure 4-4

.

Figure 4-4 Grid Radio Buttons and Check boxes

Advertising