Instrument components and specifications, 1 technical data, Technical data – Leica Biosystems TP1020 User Manual

Page 13

Advertising
background image

13

Leica TP1020

3.1 Technical data

Type TP1020

Approvals ..........................................................................................................................................UL / cUL / VDE

Electrical data

Nominal voltage ...................................................................................................100 / 120 / 230 /240 V AC ±10 %

Rate frequency ..........................................................................................................................................50 - 60 Hz
Power fuses (Type MDA; Bussmann) ..................................................................

2x T 10.0 A L250 V, UL listed

Nominal capacity ...........................................................................................................................................700 VA

Classifications according to IEC-1010/EN61010-1:

Protective class.........................................................................................................................................................I

Pollution degree .......................................................................................................................................................2

Overvoltage category ............................................................................................................................................. II

Heat emission (max.) .................................................................................................................................... 700 J/s

Operating temperature range ..............................................................................................................5 °C – 40 °C

Relative humidity ................................................................................................................. 80 % non-condensing

Dimensions

Carousel lid ................................................................................................................................................820 mm Ø

Height ....................................................................................................................................................595 - 780 mm

Pitch diameter of rollers ...................................................................................................................... 610 mm Ø

Weight

Net weight (including accessories) ...............................................................................................................60 kg

Net weight, including packaging material .............................................................................................. 116 kg

Wax baths

Quantity:.............................................................................................................................................2 (optionally 3)

Capacity: ...............................................................................................................................................................1.8 l

Nominal voltage / rated frequency: .......................................................................................230 V AC, 50-60 Hz

Nominal capacity per station: ......................................................................................................................150 VA

Temperature setting range ....................................................................................................45 °C – 65 °C ±3 K

Excess temperature shutdown ...........................................................................................................85 °C±5 K

3. Instrument Components and Specifications

Advertising