Leica RM2265

6. Optional Accessories

6.1.3 Fine-directional fixture for specimen

clamps

• Before the fine-directional fixture for specimen

clamps can be mounted, loosen 4 screws (10)

(Allen key No. 3) and carefully remove the fix-

ture for specimen clamps from the baseplate

(9).

10

11

• Using the 4 supplied screws (11) and the Allen

key No. 3, fasten the baseplate to the specimen

head (12).

11

• Now, screw the fine-directional fixture for

specimen clamps with the 4 screws (10) and

the Allen key No. 3 onto the specimen head.

9

12

If the fine-directional fixture for speci-

men clamps is not used, retain the base-

plate and 4 screws (11) together with

the fine-directional fixture for specimen

clamps!

Fig. 29