4.3.

Control connections axis module

4.3.1. Control terminals

Pin assignment of the control terminal block X5

4.3.2. Analog input and outputs

Analog set value selection
For analog set value provision, two inputs are available, either as
speed or torque set value provision (for selection see C005
configuration). The bipolar input is a differential input..

1

2

7

8

9

A

S

E

-

-

X5

X5

68kOhm

82kOhm

R304

44kOhm

R306

44kOhm

100kOhm

100kOhm

68kOhm

82kOhm

Master voltage
0...+10V

Master voltage
-10...+10V

a) bipolar set value selection

b) unipolar set value selection

Set value
potentio-
meter
10 kOhm/lin.

Monitor outputs
The terminals 62 and 63 of the control terminals block X5 transform
internal digital control signals into analog output signals. The
resolution is 8 bit. The signals are updated every 2ms. The
maximum monitor output current capacity is 2mA.

Output

Terminal

Signal

Range

Level

Monitor 1

X 5 62

Actual speed value

adjustable via C153/C154 -10V...+10V

Monitor 2

X 5 63

Torque set value

-Mmax...+Mmax

-10V...+10V