Parameter setting, Lcd display – Lenze 9228E User Manual

Page 42

Advertising
background image

40



Parameter setting

1. LCD

display

Ready (green)
Curr. limit I

max

(red)

Im pu lse in hib it
(ye llow )

Keys

SH

STP

PRG

1.1.

Key functions

Key

Function

PRG

Change between code and parameter level

▲

Increase displayed value

▲

+ SH

Rapid increase of displayed value

▼

Reduce displayed value

▼

+ SH

Rapid reduction of displayed value

SH + PRG

Execute change. Reset after fault indication

STP

Inhibit controller (see note below)

SH + STP

Enable controller

Note

•

For the execution command SH+PRG and the enable command SH+STP first
press the SH key and hold, than press the PRG or STP key.

•

When inhibiting the controller by pressing the STP key, it must be enabled
again by using the SH+STP command. Only then can it be
enabled via terminal 28 or interface.

1.2.

Plain-text display

The LCD display constists of two lines of 16 characters each. In the
upper line, code no. and parameter are displayed. The arrow >
shows the present level (code or parameter level), which can be
changed when pressing the

▲

or

▼

key. In the lower line, the

codes or parameters are explained.

-Arrow for code level-

↓

-Code no.-

-Parameter-

> C 0 0 1

- 0 -

O p e r a t i n g

m o d e

-Explanatory text-

Fehler! Es

ist nicht

möglich,

durch die

B

b it

Advertising
This manual is related to the following products: