Lenze 9228E User Manual

Page 68

Advertising
background image

66



Code Name

Parameter

Accept-
ance

see
page

C041

CW/CCW

-0-
-1-

Set value not inverted
Set value inverted

SH+PRG

C042

QSP (Quick
stop)

-0-
-1-

Quick stop inactive
Qick stop active (The speed set value
goes to digital 0 with the quick stop
deceleration time under C105)

SH+PRG

C043
(L)

Trip Reset

-0-
-1-

no act. fault/ reset fault
actual fault

ON-LINE

C045

JOG enable

-0-
-1-

JOG set value inhibited
JOG set value enabled

SH+PRG

C046

n

set

1

(speed set
value 1)

xxxx

Setting range: -n

max

...+n

max

Step:

1 rpm

Display of the externally adjusted
speed set value. For keypad and
LECOM control: on-line set value
selection

ON-LINE

C047

M

max

(torque limit)

xxx

Setting range: 0...100.0% or
-100.0...+100.0% for torque control
Step:

0.1%

The maximum torque which can be
obtained, depends on the type of
servo motor and the axis module
employed

ON-LINE

C050

n

set

2 (speed

set value 2)

_xxxx

Setting range: -n

max

...+n

max

Step:

1 rpm

Effective speed set value at speed
controller input

read only

C051

n

act

(motor

shaft speed)

_xxxx

Setting range:

-9765...9765 rpm

Step:

1 rpm

read only

C054

I

mot

(motor current)

xxx

Setting range: 0.0...maximum

current

Step:

0.1 A

The displayed value is calculated
from the sinus oscillations of the
current. the difference to the actual
effective motor current is approx.
10%. In the field weakening range, a
larger difference may be possible.

read only

C056

M

set

(effective
torque set
value)

xxx

Setting range: -100.0...+100.0%
Step:

0.1%

The maximum torque which can be
obtained (100%) depends on the type
of servo motor and the axis module
employed

read only

C059* Pole pair

number

xx

read only

C060* Rotor position

xxxx

Setting range:

0...2047 increments

Step:

1 increment

read only

Advertising
This manual is related to the following products: