Lenze 9228E User Manual

Page 69

Advertising
background image

67



Code Name

Parameter

Accept-
ance

see
page

C061

Utilization I x t

xxxx

Setting range: 0.0...+100.0%
Step:

0.1%

The indicated value is determined by
the current-time integral I x t of the
controller current. When reaching
100% the I x t monitoring sets
overload trip

read only

C067

Fault diagnosis

xxx

see under "Service"

74

C068
(L)

Operating state

see under "Service"

read only

59

C069
(L)

Controller state

see under "Service"

read only

59

C070

V

pn

(gain of

speed
controller)

30

Setting range: 0...500
Step:

1

ON-LINE

49

C071* T

n

(Integral action
time of speed
controller)

10

9999

Setting range: 2.5...100 ms
Step:

0.5 ms

Deactivate integral component

ON-LINE

49

C072* k

d

(differential
amplification of
speed
controller)

0

Setting range: 0...5
Step:

0.1

ON-LINE

49

C079* V

p

(V

z

-controller)

1000

Setting range: 0...9000
Step:

1

ON-LINE

53

C080* T

n

(V

z

-controller)

1.0 s

Setting range: 0.01...150

ON-LINE

53

C081* Rated motor

power

xxx.x

Setting range: 0.1...650 kW
Step:

0.1 kW

47

C087

Rated motor
speed

xxxx

Setting range: 300...6000 rpm
Step:

1 rpm

C088

Rated motor
current

xxx

Setting range: 0.1A...max. controller
current
Step:

0.01 A

C089

Rated motor
frequency

xxx.x

Setting range: 10.0...300.0 Hz
Step:

0.1 Hz

C091

cos

ϕ

Motor

x.xx

Setting range: 0.50...0.99
Step:

0.01

C093* Controller

identification

xx

read only

C094* Pass word

0

enter any password (0...999)
no password defined

SH+PRG

42

C098

Language

-0-
-1-
-2-

German
English
French
Note:
The setting will not be overwritten
when loading the factory setting!

C099* Software

version

92_5.x Number to identify the software

version

read only

C105

Quick stop
deceleration
time T

QSP

0.01

Setting range: 0.00...990 s
Step:

0.01 s from 0.00...1 s

0.1 s from 1...10 s
1 s from 10...100 s
10 s from 100...990 s

ON-LINE

48