Code table – Lenze 9228E User Manual

Page 65

Advertising
background image

63



6.

Code table

The following table shows which settings can be performed with
which codes. Detailed explanation about the codes and the
functions which can be achieved, are described in special chapters.
For the acceptance of parameters see page 41.

How to read the code table:

Column

Short form Meaning

Code

C000
C017*
C043 (L)

Code digit of the standard code set
Code digit of the extended code set
Code digit can only be reached via the LECOM interface; code
is not displayed

Parameter

-0-

The factory setting is printed in bold.

Acceptance ON-LINE

SH + PRG

Unit immediately accepts new parameter
Unit accepts new parameter after pressing SH+PRG
Unit accepts parameter only if the controller is inhibited when
pressing SH+PRG.

Code Name

Parameter

Accept-
ance

see
page

C000

Code set

-0-
-1-
-2-
-9-

-11-

-P-

xxx

Standard code set read only
Standard code set
Extended code set
Service code set (service password
neccessary)
Code set for
automation module
Password request
Enter password

SH+PRG
password

SH+PRG

45

C001

Operating
mode

-0-
-1-
-2-
-3-
-4-
-5-
-6-
-7-

Control:

Parameter setting:

Terminals

Keypad

Keypad

Keypad

Terminals

LECOM1

LECOM1

LECOM1

Terminals

LECOM2

LECOM2

LECOM2

LECOM2

Keypad

LECOM2

LECOM1

45

C002

Load parameter
set

-0-

Factory setting

C003

Store
parameter set

-1-

Parameter set 1

SH+PRG

C004

Switch-on
display

51

Code no. for parameter displayed
after first switch-on

SH+PRG

57