70



Code Name

Parameter

Accept-
ance

see
page

C228* Acceleration

time (V

z

-

controller)

0.01

Setting range: 0.00...990 s
Step:

0.01 s from 0.00...1 s

0.1 s from 1...10 s
1 s from 10...100 s
10 s from 100...990

ON-LINE

53

C229* Activation

V

z

-controller

-0-

-1-

Mains failure detection with V

z

-control

not activated
Mains failure detection with V

z

-control

activated

53

C236* V

set

(V

z

-controller)

600

Setting range: 300...900 V
Step:

1 V

ON-LINE

53

C237* Influence of

V

z

-control

1000

Setting range: 1...8000 rpm
Step:

1 rpm

ON-LINE

53

C249
(L)

LECOM1-code
bank

-0-
-1-
-2-
-3-
-4-
-5-
-6-
-7-

C000 to C255
C250 to C505
C500 to C755
C750 to C1005
C1000 to C1255
C1250 to C1505
C1500 to C1755
C1750 to C2000

SH+PRG

C250* Homing mode

-0-
-1-

not active
active

56

C252* Angle offset

0

Setting range: 0...2047
Step:

1

ON-LINE

56

C253* Speed-

proportional
angle offset

8.5

Setting range: -819.1...+819.1 incre-

ments (at 4000 rpm)

Step:

1

Possibility to correct an angular
offset, which is proportional to the
speed and depending on the cycle
time. The setting refers to an
incremental deviation of 4000 rpm.

ON-LINE

C254* V

pw

14

Setting range: 0...16
Step:

1

ON-LINE

56

C255* Following error

limit

10

Setting range: 10...3071 increments
Step:

1 increment

ON-LINE

57