Features of the positioning module 2211PP:

32 freely assignable digital inputs with 8 or 28 via terminals
according to variant

32 freely assignable digital outputs with 4 or 16 via terminals
according to variant

Absolute or relative measuring system

32 program sets, each with the following functions:
point to point positioning
point to point positioning with velocity profile
positioning to an interrup-input
acceleration, deceleration, traversing and final speed adjustable
waiting for input
switching of several outputs
homing according to 6 different modes
adjustable waiting time
adjustable number of pieces for repeat function
program branching depending on inputs
jump to following program set

32 adjustable positions

32 adjustable speeds

32 adjustable acceleration and deceleration values

32 adjustable number of pieces

32 waiting time

Manual and program operation

Input and display via the operating unit of the 9200 basic unit

Parameter setting and programming via the serial interface
LECOM A/B of the basic unit by means of the PC program
Lemoc2 (via menu)

Connection of a BCD switch possible

Connection of an absolute encoder possible

Control, parameter setting, and programming via Interbus-S or
Profibus possible

The function Winding calculator is available as alternative
system software on the same hardware basis as the positioning
module.

Note:
Please additionally note the Operating Instructions of the
positioning system.