Code Name

Parameter

Accept-
ance

see
page

C370* Automation

interface

-0-

-1-

Automation interface active
Automation interface inactive
The automation communication must
be activated when using an auto-
mation module or a field bus connec-
tion LECOM2. If the communication is
enabled, without communicating to
the other side, the controller remains
inhibited. The communication via the
automation interface can be activated
independently of the operatíng mode
C001 when the controller is inhibited
(C040 = 0).
Caution!
To ensure a faultless initialization, the
LECOM interface may only be
accessed after one sec.
Note:
The setting will not be overwritten
when loading factory setting!

C380
(L)

RP-set speed
(corresponds to
C046)

_xxxxx Display range:

-26844...+26844

(8000 rpm = 26844)

Step:

1

ON-LINE

C381
(L)

RP-n

set2

(corresponds to
C050)

_xxxxx Display range:

-26844...+26844

(8000 rpm = 26844)

Step:

1

read only

C382
(L)

RP-actual
speed
(corresponds to
C051)

_xxxxx Display range:

-32767...+32767

(9765 rpm = 32767)

Step:

1

Note:
Quick display without time message!

read only

C387
(L)

RP-set torque
(corresponds to
C056)

_xxxxx Display range:

-32767...+32767
(100% = 32767)

Step:

1

read only

C388
(L)

RP-M

limit

(corresponds to
C047)

_xxxxx Display range:

-32767...+32767

Step:

1

ON-LINE

C391
(L)

RP-act. angle
(corresponds to
C060)

xxxxx

Display range:

0...65535
(360° = 16384)

Step:

1

read only