Parameter setting & configuration
Homing mode
106
L
EDS94TA11010xxxx EN 1.2 - 03/2010
CiA402 Homing method 22
Processes:
Case 1:
Axis has not yet activated reference switch:
1. Movement in negative direction with profile data set 1.
2. The following positive edge of reference switch sets reference (
).
3. Absolute positioning to target position (C02643) with profile data set 2 (if
= "0").
Case 2:
Axis already stands on reference switch:
1. Movement in positive direction with profile data set 2.
2. Reversing with negative edge of reference switch.
3. The following positive edge of reference switch sets reference (
).
4. Absolute positioning to target position (C02643) with profile data set 2 (if
= "0").
Homing switch
2
1
0