8 detectundervoltage, 9 l_devapplerr1, Detectundervoltage – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 185: L_devapplerr1

EDS94TA11010xxxx EN 1.2 - 03/2010
L
185
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Parameterisable function blocks
3.21.8
DetectUnderVoltage
3.21.9
L_DevApplErr1
is ans instance of
Function
L_TbCompare_n
DC-bus undervoltage recognition
• Comparison of the current DC-bus voltage with the UG min. threshold set in
Parameter
Possible settings
Information
C04080
Comparison operation
0 dnIn1_n = dnIn2_n
1 dnIn1_n > dnIn2_n
2 dnIn1_n < dnIn2_n
Lenze setting
3 |dnIn1_n| = |dnIn2_n|
4 |dnIn1_n| > |dnIn2_n|
5 |dnIn1_n| < |dnIn2_n|
C04081
0.00
%
100.00 Tolerance
• Initialisation: 0.00 %
C04082
0.00
%
100.00 Hysteresis
• Initialisation: 0.00 %
is ans instance of
Function
L_DevApplErr
Error triggering
Application error messages ( 181)
Parameter
Possible settings
Information
C05900
980
999 Module ID
• Initialisation: 999
C05901/1...8
0
65535 Error ID
• Initialisation: 8001 ... 8008
C05902/1...8
Error response
0 None
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information