0x6091, Parameter setting & configuration factor group – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 68

9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Factor group
68
L
EDS94TA11010xxxx EN 1.2 - 03/2010
0x6091 - Gear ratio
Index | Name:
0x6091 | Gear ratio
Data type: UNSIGNED_32
Gearbox factor
Subindex Name
Motor revolutions
Shaft revolutions
Index | Name:
0x6091/1 | Motor revolutions
Data type: UNSIGNED_32
Code: C02520
Number of drive shaft revolutions
• Direct mapping of the Lenze code C02520 (gearbox factor numerator: motor).
Setting range
(min. value | unit | max. value)
Lenze setting
1
rev
2147483647 1 rev
;
Read access ; Write access ; CINH PLC-STOP PDO_MAP_RX PDO_MAP_TX
Index | Name:
0x6091/2 | Shaft revolutions
Data type: UNSIGNED_32
Code: C02521
Number of output shaft revolutions
• Direct mapping of the Lenze code C02521 (gearbox factor denominator: motor).
Setting range
(min. value | unit | max. value)
Lenze setting
1
rev
2147483647 1 rev
;