9 control commands & status information, Control commands & status information – Lenze E94AxHE Technology Application CiA402 Device profile User Manual
Page 117

EDS94TA11010xxxx EN 1.2 - 03/2010
L
117
9400 Technology applications | CiA402 device profile
Parameter setting & configuration
Homing mode
3.9.9
Control commands & status information
) serves to execute the following control commands in
the "homing mode" operation mode:
The CiA402 status word (
) serves to output the following status information for
referencing in the "homing mode" operation mode:
Control word
Status Function
Bit 4
0 Homing is not active
0 Ê 1 Start reference search
1 Ì 0 Cancel reference search
Bit 11
0 Ê 1 Set reference
Bit 12
0 Ê 1 Delete reference
Status word
Status Meaning
Bit 12
0 Homing is not active or reference search not yet completed
1 Reference search completed (observe bit 13)
Bit 13
0 Reference search has been executed successfully
1 An error has occurred during the reference search
Bit 14
0 Home position is not available
1 Home position is available