MTS Acumen User Manual
Page 64

Description
Control
Item
Indicates the minimum and maximum range allowed on the
manual control according to the selected units of measurement.
Range Minimum, Range
Maximum
4
Select the minimum range for the manual control.
Range Minimum
5
Select the maximum range for the manual control.
Range Maximum
6
Smallest increment used in the manual control range and the
distance the actuator will move when you click the slider arrows
Resolution
7
or when you click the tension or compression icons (when you
are using the dial).
Axial Force Diagram
The controls and icons described for the Axial Displacement diagram in the preceding sections also apply
to the Axial Force diagram.
The green lines in the following figures show the use of the magnification icon and the control icon.
64 | MTS Acumen
™
System Introduction