I/o configuration, Parameter 22 — devicenet voltage – Rockwell Automation 855T DeviceNet Stack Light User Manual User Manual

Page 37

Advertising
background image

Operations 4-7

Publication 855T-UM001C-EN-P May 2005

Parameter 22 — DeviceNet Voltage

This read only parameter is used for monitoring the DeviceNet voltage at the node. The
voltage reported via Parameter 22 may vary from actual voltage by up to 1V DC.

I/O Configuration

The I/O messaging is set up by the master device through client/server connections at
power-up. This device supports both Change-of-State (COS), cyclic, and Polled
I/O messaging connections. The default I/O size is one input byte and one output byte with
a polled I/O connection
The Output command is defined as follows:

Table 4.N Output Command Byte

Bit Number

Function When = 1

Function When = 0

7

6

5

4

Output 5 Execute

Output 5 Idle

3

Output 4 Execute

Output 4 Idle

2

Output 3 Execute

Output 3 Idle

1

Output 2 Execute

Output 2 Idle

0

Output 1 Execute

Output 1 Idle

Table 4.O Input Byte

Bit Number

Function When = 1

Function When = 0

7

6

5

4

Position 5 Idle, Not Present, or Burned Out

Position 5 Normal

3

Position 4 Idle, Not Present, or Burned Out

Position 4 Normal

2

Position 3 Idle, Not Present, or Burned Out

Position 3 Normal

1

Position 2 Idle, Not Present, or Burned Out

Position 2 Normal

0

Position 1 Idle, Not Present, or Burned Out

Position 1 Normal