Certifications – Rockwell Automation 855T DeviceNet Stack Light User Manual User Manual

Page 49

Advertising
background image

Specifications A-2

Publication 855T-UM001C-EN-P May 2005

Certifications

UL, CUL, and CE marked for all applicable directives. CE standards include EN55011,
EN50081-2, EN50082-2, and EN60947-5-1. This product is intended for use in an industrial
environment.

Special Notes

Refer to the Signaling Solutions Selection Guide (Publication 855-SG001*-EN-P) or the Industrial
Controls Catalog for module-specific information.

Environmental Ratings

Ingress Ratings

Pole bases

NEMA Type 4/13, IP65

All other

NEMA Type 4/4X/13, IP65

Temperature Ratings

Operating Temperature

–25…+70

°C

Storage Temperature

–40…+85

°C

Relative Humidity (Non-Condensing)

0…95% humidity

Electrical Ratings

Supply Voltage

The DeviceNet Base operates at 11…25V.

Power Consumption

Maximum with five modules

36 W, 1.75 W in idle mode

Outputs (Modules)

Up to five modules will be supported. The voltage
and current rating is 24V DC/300 mA maximum. All
standard 24V module types will be supported.
Refer to 855T catalog for module-specific
information.

DeviceNet Connection Cables

Three styles of DeviceNet connection cables will
be supported. A one meter micro-style connector, a
one meter mini-style connector, and a two meter
open-style cable will be supported. They will
consist of a 22 AWG drain wire, a 24 AWG twisted
pair for communications, and a 22 AWG twisted
pair for power. There is a 3 A maximum rating on
the power pair.

Flash Upgrade Frequency

Memory may be upgraded 100 times without
corruption of data.

Communications

Data Rates

125 KB, 250 KB, and 500 KB

Distances

500 m (1600 ft)

125 KB

200 m (600 ft)

250 KB

100 m (300 ft)

500 KB

Table A.1