Rockwell Automation 855T DeviceNet Stack Light User Manual User Manual
Page 56
Advertising
B-7 DeviceNet Information
Publication 855T-UM001C-EN-P May 2005
➊ The data for off_delay is time in microseconds, valid values: 0, 2000, 4000, 8000, 16000.
➋ The data for on_delay is time in microseconds, valid values: 0, 2000, 4000, 8000, 16000.
➌ Disable Autobaud: 0 = Enabled, 1 = Disabled
➍ Fault State: 0 = Reset Outputs, 1 = Hold Last State
➎ Idle State: 0 = Reset Outputs, 1 = Hold Last State
Common Services
Table B.11 Assembly Object, Instance 104 Attributes
Attribute
Access
Name
Type
Value
3
Get/Set
Data
Off_delay
On_delay
Autobaud
DOG_Fault_State
DOG_Idle_State
STRUCT of:
UINT
UINT
BOOL
BOOL
BOOL
➊
➋
➌
➍
➎
Table B.12
Service Code
Class
Instance
Service Name
14 (0x0E)
Yes
Yes
Get_Attribute_Single
16 (0x10)
No
Yes
Set_Attribute_Single