B-9 DeviceNet Information

Publication 855T-UM001C-EN-P May 2005

Instance 2 is the Predefined Group 2 Connection Set Polled I/O Message Connection. The
following instance 2 attributes will be supported:

Table B.14

Attribute
ID

Access
Rule

Name

Data Type

Value

1

Get

State

USINT

0 = nonexistent
1 = configuring
3 = established
4 = timed out

2

Get

Instance Type

USINT

1 = I/O Connection

3

Get

Transport Class Trigger

USINT

0x82 — Server,
Transport Class 2
(If alloc_choice ! =
polled and ack
suppression is enabled
then value = 0x80)

4

Get

Produced Connection ID

UINT

01111xxxxxx
xxxxxx = node address

5

Get

Consumed Connection ID

UINT

10xxxxxx101

xxxxxx = node address

6

Get

Initial Comm. Characteristics

USINT

0x21

7

Get

Produced Connection Size

UINT

0…8

8

Get

Consumed Connection Size

UINT

0…8

9

Get

Expected Packet Rate

UINT

In milliseconds

12 (0C

hex

)

Get/Set

Watchdog Action

USINT

0 = transition to timed
out
1 = auto delete
2 = auto reset

13 (0D

hex

)

Get

Produced Connection Path
Length

UINT

6

14 (0E

hex

)

Get/Set

Produced Connection Path

20 04 24
(assy inst #) 30 03

15 (0F

hex

)

Get

Consumed Connection Path
Length

UINT

6

16 (10

hex

)

Get/Set

Consumed Connection Path

20 04 24
(assy inst #) 30 03

17 (11

hex

)

Get/Set

Production Inhibit Time

UINT