Additional resources – Rockwell Automation 1756-L7x GuardLogix 5570 Controllers User Manual
Page 135

Rockwell Automation Publication 1756-UM022A-EN-P - November 2012
135
Change Controller Type
Appendix B
• The safety partner is created in slot x (primary slot + 1) when changing
from a 1768 Compact GuardLogix to a GuardLogix 5570 controller.
• When changing to a 1768 Compact GuardLogix controller, the safety
partner is removed because it is internal to the Compact GuardLogix
controller..
Floating-point instructions, such as FAL, FLL, FSC, SIZE, CMP, SWPB, and
CPT are supported in GuardLogix 5570 controllers, but not in GuardLogix
5560 and 1768 Compact GuardLogix controllers. If your safety program
contains these instructions, verification errors will occur when changing
from a GuardLogix 5570 controller to a GuardLogix 5560 or
1768 Compact GuardLogix controller.
Additional Resources
Refer to the Logix5000 Controllers Add-On Instructions Programming Manual,
publicatio
, for more information on Add-On Instructions.
TIP
A GuardLogix 5570 controller supports 100 safety programs in the safety
task while a 1768 Compact GuardLogix controller supports 32.