Chapter 3

Constructing a Data Highway or

Data Highway Plus Cable System

3-4

If you have a 15-socket connector, continue with step 7. If you do not have a
15-socket connector, continue with step 9.

7.

Remove the screws that attach the right-angle hood to the 15-socket
connector and separate the hood from the connector.

Large-diameter

Shrink Tubing

(clear plastic)

Small-diameter

Shrink Tubing

(clear plastic)

Small

Screws

Locking Clip

Locking Clip

Cable Clamp

Large Screw

Pin

Holes

Right-angle Hood

10806

8.

Guide the dropline through the circular hole in the right-angle hood.

9.

Keeping the pins on the electrical connector facing up, clamp the
connector securely in a vise. Do not over-tighten the vise.

10.

Cut the small-diameter shrink tubing into three equal pieces, and slip one
piece over the drain wire, one piece over the blue conductor wire, and one
piece over the clear conductor wire.

If you have this connector:

Go to step:

3Ćposition terminal block

11

9Ćpin

12

15Ćsocket

13

62Ćpin

14