Enabling Switch Operation
The actuating element consists of two symmetrically arranged slides.
The position of these slides is detected by electrical switches and
transmitted to the evaluation electronics.
Positions of Enabling Switch
For the enabling switch, the following switch sequences are possible:
A. Home position
enabling
panic
home position (1-2-3-1)
B. Home position
enabling
home position (1-2-1)
The pushing of the actuating elements directly into the panic position
is evaluated in a way that the enabling position is skipped when the
actuating elements are released.
Home Position (1)
enabling outputs are open
Enabling (2)
enabling outputs are closed
Panic (3)
enabling outputs are open
x
u
v
x
y
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
Circuit 1
Circuit 2
1
2
3
Circuit X = open
Circuit X = closed
a)
b)
ZT1
ZT2
ZT1
ZT2
ZT1
ZT2
ZT1
ZT2
x
u
x
v
y
1
2
3
ZT1, ZT2
ZT1, ZT2
ZT1, ZT2
ZT1, ZT2
a)
b)
1
2 3 1 2 3
Contact Travel Diagram