Mounting and connecting the junction box, Mounting and connecting the junction box -2, Attention – Rockwell Automation 2727-G7P20D3Q7 MobileView G750 Guard Machine Terminal User Manual

Page 30

Advertising
background image

Publication 2727-UM002D-EN-P

3-2 Terminal Connections

Mounting and Connecting
the Junction Box

The MobileView Junction Box (2727-MRJB1) integrates the
MobileView terminal into the control system. It mounts on a DIN rail
inside an enclosure and has the following connectors:

Connectors

Description

S1

RJ-45 jack for connecting the MobileView data lines.

S2

9-pin DSUB female connector (for future use).

S3

RJ-45 jack to Ethernet network.

X1

12-pin male connector for connecting the Junction Box Cable.

X2

12-pin male connector (shipped with a female terminal block connector)
for connecting the:

• 24V dc power supply

• emergency stop switch

• enabling switches

24V D C

ON LY

TER M IN AL IN

R S422 OUT

ETH ER N ET O U T

+24V

GND

ES1+

ES1-

ES2+

ES2-

ED1 +

ED1 -

ED2 +

ED2 -

+24V

GND

ES1+

ES1-

ES2+

ES2-

ED1 +

ED1 -

ED2 +

ED2 -

X2

(with Female

Terminal Block

Connector K4)

S1

S2

S3

Junction Box

Pin 1, 24V dc

Pin 1, 24V dc

16

2 mm

(6

.4

in

.)

X1

(with Female

Terminal Block

Connector K3)

108 mm (4.25 in)

150 mm (5.91 in)

60 mm (2.36 in)

DIN Rail Latch

Grounding Screw Strain Relief

for Cable

Grounding Screw

ATTENTION

!

The MobileView Junction Box and the MobileView
terminal meet the safety class III in accordance with
EN 61131-2 and EN 50178.

When connecting the terminal, make sure all
voltages connected to the MobileView terminal are
safety extra low voltages and isolated from the low
voltage supply system by a safety transformer or a
similar safety component.

Advertising