Using RSView ME Station 5-7

Loading an ME Application

To load an RSView ME .MER application, select the Load Application
button on the main screen:

1. Select the Source button to select the storage location of the

application file you want to load. The options are:

• Internal Storage - the Internal Flash in the MobileView terminal.
• External Storage 1 - the External PCMCIA Flash card loaded in

the card slot of the terminal.

• External Storage 2 - not supported by MobileView products.

2. Select an .MER file from the list. Use the up and down cursor

keys to select a file.

3. Select the Load button to load the application.

You will be asked if you want to replace the terminals’ current
communication configuration with the application’s
communication configuration.

4. Select Yes or No. If you select Yes, any changes made to the

device addresses or driver properties in the RSLinx
Communications screen will be lost.

The name of the currently loaded application will appear at the top of
the main RSView ME Station screen.

Moves

highlight up

Moves

highlight down

List of .mer applications
stored in the compact
flash of the terminal.