Mobileview connection cable -7, Mobileview connection cable – Rockwell Automation 2727-G7P20D3Q7 MobileView G750 Guard Machine Terminal User Manual

Page 35

Advertising
background image

Publication 2727-UM002D-EN-P

Terminal Connections 3-7

MobileView Connection Cable

The Mobile Connection Cable (2727-MRTxx) connects the MobileView
terminal to the MobileView Junction Box Cable (2727-MREX1). The
Connection Cable is 5, 10, 15, or 20 meters (6.4, 32.8, 49.2 or 65.6 ft).
This cable withstands water, cleaning agents, motor oil, drilling oils,
grease, lubricants and condensates containing hydrochloric acid.

K1

17-pin Circular

Connector Pin #

MobileView

Connection Cable

Wire Color

K3, 11-pin Female

Connector

to S19 in

Terminal

K2, 8-pin

RJ-45 Jack

Ethernet to S4 in

Terminal

Signal

Description

1

pink

-->>

6

-

24V DC

2

black

-->>

7

-

GND_IN

3

green-brown

-->>

8

-

E-stop, circuit 1, positive

4

white-green

-->>

9

-

E-stop, circuit 1, negative

5

grey-pink

-->>

10

-

E-stop, circuit 2, positive

6

red-blue

-->>

11

-

E-stop, circuit 2, negative

7

brown

-->>

1

-

enabling switch, circuit 1, positive

8

yellow

-->>

2

-

enabling switch, circuit 1, negative

12

green

-->>

3

-

enabling switch, circuit 2, positive

17

grey

-->>

4

-

enabling switch, circuit 2, negative

9

bridge to pin 10

-->>

-

-

not used

10

bridge to pin 9

-->>

-

-

not used

11

violet

-->>

5

-

not used

13

blue

-->>

-

1

TD+ (transmit)

14

white

-->>

-

2

TD- (transmit)

15

orange

-->>

-

3

RD+ (receive)

16

red

-->>

-

6

RD- (receive)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

K2, 8-pin
RJ-45 jack to S4
at MobileView
terminal

5, 10, 15, or 20 meter (6.4, 32.8, 49.2, or 65.6 ft)

K3, 11-pin
female connector
to S19 at MobileView terminal

K1, 17-pin circular connector
view from connector side

Advertising