Loading a new image file -7, Loading a new image file – Rockwell Automation 2727-G7P20D3Q7 MobileView G750 Guard Machine Terminal User Manual

Page 51

Advertising
background image

Publication 2727-UM002D-EN-P

Configuring the MobileView Terminal 4-7

Loading a New Image File

The Image Update tab allows selection, validation, and loading of a
new WinCE Flash image file to the MobileView terminal.

You can update the image directly from a PC card or using an
Ethernet or Serial connection download the update file to the
MobileView Terminal. Do not remove the PC card until the image
update procedure is complete.

Interruptions may occur when downloading large files over Ethernet
connections using two or more switches.

1. Tap the Image Update tab.

2. Tap the Image File button. Browse and select the .bin file, then

tap the Start Update button.

• Tap the OK button to stop the IPSM. The message “PSM

deactivate” appears.

• Tap the OK button to quit and reset the terminal. If the terminal

did not reset, the file SoftReset.exe will not copy to the
terminal’s root directory.

• Select Start>Programs>MobileView>MV Configuration Tool
• Repeat step 1.

IMPORTANT

If the IPSM is still formatting the flash area, you will
see the message, “PSM is active. Do you want to
deactivate PSM and reset the device?”. Follow the
bulleted procedure. If this message does not appear,
proceed with step 3.