4-6 Configuring the MobileView Terminal

You can select the following startup actions for the MobileView
terminal:

Update OS Image on Next Startup - Loads the OS (Operating

System) image from the BOOTP Server via the network the next
time the MobileView is started.

• Disable internal network controller: - Deactivates the internal

Ethernet interface CELAN1:Onboard Ethernet at the next startup.

To enable the network controller after disabling:

a. Deselect “Disable Internal Network Controller”.

b. Perform a registry backup by selecting

Start>Programs>MobileView>Registry Backup.

c. Cycle power to the MobileView terminal.

Activating/Testing Pushbutton LEDs

The Pushbuttons tab allows activation of the push button LEDs, that
are present, on the MobileView terminal.

Tap one of the 3 pushbutton targets to switch the corresponding LED
to Flashing, On, or Off. The first tap switches the LED to Flashing, the
second tap switches the LED to On, and the third tap switches the
LED to Off.

IMPORTANT

The Ethernet connection must have been
established, the BOOTP Server must be correctly
configured, and an OS image file must be available.
See the MobileView G750/MT750 Flash Update
documentation for more information.

IMPORTANT

This activation test utility activates the push button
LEDs only. The push button and keyswitch position
states are not affected.