Activating/testing pushbutton leds -6, Activating/testing pushbutton leds – Rockwell Automation 2727-G7P20D3Q7 MobileView G750 Guard Machine Terminal User Manual
Page 50

Publication 2727-UM002D-EN-P
4-6 Configuring the MobileView Terminal
You can select the following startup actions for the MobileView
terminal:
• Update OS Image on Next Startup - Loads the OS (Operating
System) image from the BOOTP Server via the network the next
time the MobileView is started.
• Disable internal network controller: - Deactivates the internal
Ethernet interface CELAN1:Onboard Ethernet at the next startup.
To enable the network controller after disabling:
a. Deselect “Disable Internal Network Controller”.
b. Perform a registry backup by selecting
Start>Programs>MobileView>Registry Backup.
c. Cycle power to the MobileView terminal.
Activating/Testing Pushbutton LEDs
The Pushbuttons tab allows activation of the push button LEDs, that
are present, on the MobileView terminal.
Tap one of the 3 pushbutton targets to switch the corresponding LED
to Flashing, On, or Off. The first tap switches the LED to Flashing, the
second tap switches the LED to On, and the third tap switches the
LED to Off.
IMPORTANT
The Ethernet connection must have been
established, the BOOTP Server must be correctly
configured, and an OS image file must be available.
See the MobileView G750/MT750 Flash Update
documentation for more information.
IMPORTANT
This activation test utility activates the push button
LEDs only. The push button and keyswitch position
states are not affected.