147

Scrolling Lists

Publication 2711E-6.15 – November 1998

In this example you can use a momentary button identified as
TOGGLE COMMAND to toggle and display between “Select” and
“Bypass” for the station currently selected by the cursor. Another
momentary button, labeled SET COMMAND, activates the toggled
command.

You can also modify the command for the station currently selected
by pressing the standard momentary buttons “Manual On” or
“Manual Off”. The PLC uses the Cursor Indicator Address to change
the selected station’s command.

Option Style Number

A Numeric Display Object List displays the style numbers of the
currently visible stations. The values displayed in this list also
depend on cursor movement.

The Numeric Keypad Enable Button allows you to modify the style
number of the selected luxury option station in manual mode.

Assigning Addresses for Object Lists

These tables list the addresses and files used in the example PLC
program for each of the object lists.

The following table displays the addresses for each of the object
lists:

Object List

Visible State
BLK Transfer
Start Address

Number of
Contiguous
Addresses

Number of
Bits per
Address

Visible State
PLC Start
Address

ASSEMBLY
STATION
Numeric
Display

BO51

5

16

N30:11

LUXURY
OPTION
Local Message

BO56

5

16

N30:16

STATION
STATUS
Multistate
Indicator

BO511

5

16

N30:21

OPTION
COMMAND
Multistate
Indicator

BO516

5

16

N30:26

OPTION
STYLE NO.
Numeric
Display

BO521

5

16

N30:31