Rockwell Automation 2711E-ND1 Reference Manual PanelBuilder 1400e User Manual
Page 163
Advertising
![background image](/manuals/580367/163/background.png)
157
Scrolling Lists
Publication 2711E-6.15 – November 1998
Create the Auto Mode Simulation Rungs
Rungs 2:11 through 2:14 simulate a sequential process. This is for
example purposes only.
Rung 2:11 sets a variable N30:8 to 1 when an Auto mode restart
occurs. This sets up a station status reset in the next rung.
23720
Rung 2:11
R38:0
] [
DN
MOV
MOVE
Source
Dest
1
N30:8
57
EQU
EQUAL
Source A
Source B
R38:0.POS
5
0
Rung 2:12 resets all STATION status indicators to “Stand-By” whose
Station Commands are “Select”.
23721
Rung 2:12
2
[ LBL ]
R38:0
] [
MOV
MOVE
Source
Dest
1
N33[N30:8]
1
EQU
EQUAL
Source A
Source B
R38:0.POS
5
0
DN
EQU
EQUAL
Source A
Source B
N34[N30:8]
1
1
ADD
ADD
Source A
Source B
Dest
1
N30:8
57
N30:8
57
LES
LESS THAN
Source A
Source B
N30:8
57
57
2
(JMP)
Advertising