153
Scrolling Lists
Publication 2711E-6.15 – November 1998
Rung 2:6 toggles the command between “Select” and “Bypass” for
the currently selected station.
23702
Rung 2:6
MANUAL
MODE
B40
] / [
1
TOGGLE
COMMAND
BUTTON
N30:3
] [
3
TOGGLE
COMMAND
ONE SHOT
B40
[ONS]
4
2
1
EQU
EQUAL
Source A
Source B
N34[N30:1]
1
1
MOV
MOVE
Source
Dest
N34[N30:1]
1
(JMP)
PRE-TOGGLE
LATCH
B40
] [
6
1
1
GEQ
GRTR THAN OR EQUAL
Source A
Source B
MOV
MOVE
Source
Dest
N34[N30:1]
N34[N30:1]
1
2
PRE-TOGGLE
LATCH
B40
] / [
6
MOV
MOVE
Source
Dest
N34[N30:1]
1
N31:202
1
MOV
MOVE
Source
Dest
2
N34[N30:1]
1
EQU
EQUAL
Source A
Source B
N31:202
1
1
MOV
MOVE
Source
Dest
N30:1
1
N31:200
3
PRE-TOGGLE
LATCH
B40
( L )
6
MOV
MOVE
Source
Dest
1
N34[N30:1]
1
GEQ
GRTR THAN OR EQUAL
Source A
Source B
N31:202
1
2