Step 3: program the plc – Rockwell Automation 2711E-ND1 Reference Manual PanelBuilder 1400e User Manual
Page 155

149
Scrolling Lists
Publication 2711E-6.15 – November 1998
Step 3: Program the PLC
To program the PLC, follow the ladder diagrams shown in the
following pages.
Create the Block Transfer Rungs
The illustration below shows the Rungs 2:0, 2:1, and 2:2. These three
rungs read and write Scrolling List data to and from the PanelView
terminal. This is a bi-directional block transfer. For more information
about block transfers, see Chapter 2, “Planning Applications,” in the
PanelBuilder 1400e Configuration Software for Windows User
Manual.
FAL
FILE ARITH/LOGICAL
Control
Length
Position
Mode
Dest
Expression
#N37:1
(EN)
23669
BTR
BLOCK TRNSFR READ
Rack
Group
Module
Control Block
Data File
Length
Continuous
Rung 2:0
READ
ENABLE
N36:0
] / [
15
WRITE
ENABLE
N36:5
] / [
15
01
6
1
N36:0
N37:1
4
N
(DN)
(ER)
(EN)
BTW
BLOCK TRNSFR WRITE
Rack
Group
Module
Control Block
Data File
Length
Continuous
Rung 2:1
READ
ENABLE
N36:0
] / [
15
WRITE
ENABLE
N36:5
] / [
15
01
6
1
N36:5
N30:10
30
N
(DN)
(ER)
(EN)
Rung 2:2
READ DONE
N36:0
] [
13
R38:5
4
3
ALL
#N30:1
1
(DN)
(ER)
MOVE READ
FILE TO
“VERIFIED”
READ FILE