The CPU temperature must be less than 95 °C (203 °F).
The battery voltage must be at least 2.75V DC.

2. Press Memory Allocation to view the following memory data:

Amount of allocated program memory
Amount of program memory in use
Amount of available nonvolatile memory

3. Press Close to return to previous dialog box.
4. Press Runtime RAM Usage to troubleshoot runtime anomalies by showing

the amount of RAM used by your application at runtime.

5. Press OK to return to previous dialog box.
6. Press Close until you return to terminal settings.

Battery State

Description

Good

Good battery condition.

Failing

Low battery. Replace the battery.

Bad

Battery is missing or bad. Replace the battery.