Defining Strings for Serial Ports and Viewports
8–26
The
Repeat String
feature enables the CVIM module to repeat a particular
string multiple times for the same event (see “Defining the Event” in this
chapter). This is accomplished through the use of an “index” number, which
is incremented through a range of values – you define this range using the
Repeat String
menu.
Repeat String box
Repeat String menu
In configuring the repeat range for a string, you set the
Start
, the
End
, and
the
Increment
values:
Start value
End value
Increment value
During operation in the run mode, when the event conditions are satisfied for
sending the string, the index is set to the
Start
value, then:
(1) If the
End
value is greater than or equal to the
Start
value, the string
is sent.
(2) The index is incremented (according to the
Increment
value).
The string is sent for each index value, until the index value exceeds the
End
value.
For example, to repeat a string 5 times, you can set the
Start
value to 1, the
End
value to 5, and the
Increment
to 1. The index will increment through
values 1 to 5. Or, you can set the
Start
value to 6, the
End
value to 10, and
set the
Increment
to 1, so the index will increment from 6–10, and so forth.