Rockwell Automation 5370-UPK CVIM USER-PAK Option User Manual
Page 108
Chapter 8
Defining Strings for Serial Ports and Viewports
8–32
Finally, recall that, for this example, the string is to be transmitted only
when the inspection fails. In order to accomplish this, we must specify
the event using the
Event
menu.
The following diagram shows that
Master Range
and
Print on Fail
have
been selected on the
Event
menu; with the event thus specified, the string
is transmitted only when the master range fails – that is, when the
inspection fails:
Event menu
Print on FAIL selected
Master Range selected
Print Every 1 selected
Tool Set 1 selected
Note also that
Print Every 1
and
Print for TS1
are selected – these
parameters specify that the string is transmitted each time the event occurs
within toolset 1, and that data codes apply only to tools in toolset 1. This
setting is appropriate if the gages in our example are configured as part of
tool set 1.