Chapter 7
Creating Custom Runtime Displays
7–21
setting other than
Disabled
(
Dot
or
Line
), which selects the style, enables
the variable, and also enables the rest of the
Define Graph Var.
menu.
Picking the
Style
box repeatedly cycles the box through three settings:
•
Disabled –
Disables the variable, as well as the remainder of the menu.
•
Dot Graph –
Plots the variable as a series of dots, one dot per result.
•
Line Graph–
Plots the variable as a continuous line.
Selecting either the
Dot Graph
or the
Line Graph
option automatically
enables the remainder of the
Define Graph Var.
menu.
Below are examples of
Line
Graph
and
Dot Graph
styles:
Graph Viewport
Example Line Graph
Example Dot Graph
Selecting Variable
Color
You further define appearance of the variable by selecting the
Color
; this is
the color of the line or dot graph created during run time. To select the color
for a graph variable:
•
Pick the
Color
menu item, which displays a
Color Selection
menu.
•
Pick the box for the desired color.
Color box
Color Selection
menu
Selecting
Clear
: If
Clear
is selected, the variable color will be green,
yellow, or red based on tool status –
Pass
,
Warn
, or
Fail
, respectively.