Use CIP Symbolic Client Messaging Chapter 2

3. Set the value for the A_SymCfg

input variable as shown.
See

SymbolicCfg on page 36

for

parameter details and
description.
Leave the initial value of
A_SymCfg.Count at 0. The
value of 1 is used for count if this
value is left at the default value
of 0.

4. Set the value for the A_TarCfg

input variable as shown.
See

TargetCfg on page 37

for

parameter details and
description.
Set A_TarCfg.ConnClose to
False. By default, this variable is
set to false.

5. Next, build and download the

project to Controller A.

IMPORTANT

The value for A_Data input variable is automatically obtained from the
COP instruction in rung 1.

Note that USINT is 8-bit data (whereas A UDINT is 32-bit data), so the
A_Data input variable is a one-dimension array with four elements.