Appendix F Programming Tips and Recommendations for Micro800 CIP Messaging Instructions (MSG)

2. Connected Components Workbench flexibly supports Array elements

starting from 0 or any non-zero number. Below are some valid examples.

3. When copying the source array from the middle of an array, use SrcOffset

to specify how many elements you need to offset. For example, if the
Source array is SrcArray[1..5] and SrcOffset is 2, then the first element to
be copied to destination is array[3].

IMPORTANT

Array in Connected Components Workbench is defined as
ArrayName[x...y], where:
x – Starting element number
y – End element number

Advertising