4. To store copied data to the Destination array, start at the middle of the
array. Use DestOffset to specify how many elements you need to offset.
For example, if the Destination array is DestArray[1..3] and SrcOffset is 1,
then the first location to store copied data is DestArray[2].
SrcArray[1 …5]
USINT
DestArray[1 …3]
USINT
SrcArray[1 …5]
USINT
DestArray[1 …3]
USINT
COP Instruction