Installing the LonWorks Module in the Drive

3-9

Step 4.

Install the LonWorks Module in the Keypad Bracket

Refer to figure 3.4 for component locations.

Step 4.1 Remove the LonWorks module from its anti-static wrapper. Align the key on

the Regulator board’s 34-conductor ribbon cable connector with the slot in
the LonWorks module’s connector. Press the ribbon cable connector in until
it locks into position.

Step 4.2 Route the 26-conductor ribbon cable for the Current Feedback board out of

the side of the keypad bracket.

!

ATTENTION: The drive contains ESD- (Electrostatic Discharge)
sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing the drive. Erratic machine
operation and damage to, or destruction of, equipment can result if this
procedure is not followed. Failure to observe this precaution can result
in bodily injury.

Figure 3.4 – LonWorks Module Location in 7.5 to 10 HP Drives

Side View

Front View

Top View

LonWorks Module

Regulator Board

LonWorks Module

Current Feedback Board