Operating the Drive Using a LonMark Profile

7-13

Generic Parameter Register Setting, Read

Definition:

network input config SNVT_count nciParRdAddress;

Explanation:

Selects register in the drive to read. The first digit is the drive
drop number. The remaining digital represent the register. For
example, 203 = drop 2, register 3. See section 8.6 for more
information.

Default:

Read from drive

Range:

000-063 = Drop 0
100-163 = Drop 1
200-263 = Drop 2
300-363 = Drop 3

Speed Setpoint Scaling Default Value

Definition:

network input config SNVT_lev_percent nciDrvSpeedScale

Explanation:

Sets its (?) value to nviDrvSpeedScale on every start up. See
Speed Setpoint Scaling in section 7.1.

Range:

-163% to 163%

Default:

0