Auto-cut 200 xt, Work tip el ec tro de, Hct1 – Tweco 200 XT Auto-Cut 400V User Manual

Page 117: W1a w1b w1c

Advertising
background image

AUTO-CUT 200 XT

Manual 0-5284

APPENDIX

A-35

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

F

F

E

E

D

D

C

C

B

B

A

A

Rev

Revision

By

Date

Rev

Revision

By

Date

042X1350

C

1

2

04/18/2012

DAT

Victor Technologies Headquarters

16052 Swingley Ridge Road, Suite 300

St Louis, Missouri 63017 USA

Drawn

Date

Sheet

of

Size

Drawing Number

SCHEMATIC

Auto-Cut XT 200A CE 380-415 VAC

The information contained herein is proprietary to Victor Technologies.

Title

Not for release, reproduction or distribution without written consent.

9/30/2013

Date Printed

Date Revised

9/16/2013

Rev

Revision

By

Date

Rev

Revision

By

Date

Drawn

Date

Sheet

Size

Drawing Number

Title

Date Printed

Date Revised

00

Initial Design

DAT

4/18/2012

Work

Tip

El

ec

tro

de

(+)

(+)

(-)

1

2

3

4

Hall Effect Sensor

HCT1

1

TORCH

1

WORK

W1A

W1B

W1C

1

2

J105A

AC INPUT

1

2

J104A

1

2

J103A

1

2

J105B

AC INPUT

1

2

J104A

1

2

J104B

1

2

J103B

1

2

J105A

AC INPUT

J100 -- 30 CKT RIBBON

1

2

J103A

INVERTER MODULE (IM) #`1 (bottom)

J100 -- 30 CKT RIBBON

1

2

3

4

5

J102A

OUTPUT

1

2

3

4

5

J102B

OUTPUT

1

2

3

4

5

J102A

OUTPUT

ELECTRODE (-)

ELECTRODE (-)

WORK (+)

WORK (+)

SHIELD

+15 VDC

-15 VDC

COMMON

SIG (+)

TO J1 on RELAY PCB

TO CCM

CPU PCB J33

(Sht 2, C3)

TO CCM

CPU PCB

J31

(Sht 2, B3)

IM #1 Section B (upper)

IM #1 Section A (lower)

J100 -- 30 CKT RIBBON

1

2

3

4

J16

18 AWG wire

both in and out of

CB1 to J60

AC 24V- Ret -TB4-1 (Sht 2, B8)

AC 24V-TB4-2 (Sht 2, B8)

AC 120V- Ret- TB4-3 (Sht 2, B8)

AC 120V- TB4-4 (Sht 2, B8)

ARC VOLTS (TORCH)

WORK

120 VAC @ 100 ma.

24 VAC @ 1A

(52)

(49)

(51)

(56)

(57)
(58)
(59)

(60)
(61)
(62)
(63)

(51)

SYSTEM BIAS SUPPLY

+24VDC

GND

+ V

To J27 on CCM I/O PCB

TO J12

T1 PRIMARY

(Sht 2, A1)

K1A

24 VDC

24 VDC

24 VDC_RET

24 VDC_RET

MISSING PHASE a

MISSING PHASE b

AC V HIGH a

AC V LOW a

AC V LOW b

AC V HIGH b

VAC_IDA a

/ VAC_IDA b

VAC_IDB a

/ VAC_IDB b

1
2
3
4
5
6
7
8
9

10
11
12
13
14

J62

480

V

-ID

400

V

-ID

208

-230

V

-ID

CO

M

(29)

(30)

(31)

(32)

(33)

(34)

(35)

(36)

(37)

(38)

(39)

(40)

(41)

(42)

(43A)

(44A)

(48)

1

2

3

4

J61

VOLTAGE SELECTION

019X501900

K1B

1 2 3 4 5 6 7 8 9 10 11 12

J63

TO AUX TRANSFORMER

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

J60

AC INPUT

J63 = Mini-Fit Jr goes to J12 on T1 primary

400 VAC -- Single 18 AWG in pins 1 & 12

480 VAC -- Single 18 AWG in pins 1 & 12

230 VAC -- 18 AWG wires in pins 1, 6, 7, 12

(7)

(8)

(9)

(7)

(8)

(9)

1

J43

ELECTRODE

1 2 3 4 5 6 7 8 9 10

J42

TO RELAY BOARD

10 ckt Ribbon

TO J3 on RELAY PCB

TIP VOLTS

WORK

ARC VOLTS

To J24 on I-O PCB

1 2 3 4 5 6 7 8

J45

TO I/O BOARD

019X501600

1

2

3

4

5

J40

INVERTER

(51)

(53

)

(51B)

(49)

(49)

L2

HF COIL_WC

C2

T2

120 / 6000 VAC

(98)

(99)

AC 120V (Sht 2, A8)

AC 120V_RET (Sht 2, A8)

SG1

0.062"

C1

6.5K 1W

6.5K 1W

C3

PLT

NEG

CGND

TO CCM

CPU PCB

J32

(Sht 2, B3)

INVERTER 1/2 MODULE (IM) #2 (top)

(50)

(49A)

(49B)

(49C)

(51C)

(51A)

(Sht 2, D3)

(Sht 2, A6)

(Sht 2, A5)

(Sht 2, E3)

C1-3

Capacitor, 1900 pf, 15Kv. (Sht 1, A10)

C4 Capacitor, fan starting, 8uf 440VAC (Sht 2, E1)

CB1

Circuit Breaker /ON/OFF SW, 15A 480V (Sht 1, D1)

CB2-4

Circuit Breaker, 5A, 250V (Sht 2, B3)

F1, 2 Fuse, 8A, 500V, S.B. (Sht 1, E1)

FAN1, 2 Fan, Heat Exchanger , 230 VAC (Sht 2, D2)

FS1

Flow SW, 1.0 GPM (3.8 lpm), N.O. (Sht 2, A2)

HCT1

Current Sensor, Hall Effect 200A, Work Lead (Sht 1, D9)

K1 Relay, 24VAC, Inrush Control (Sht 2, B9)

L2

Inductor, HF, 400A, Water Cooled (Sht 1, A10)

L3-6 Toriod Core Common Mode Ind (Sht1 B9, B&C3)

LS1

Level Switch, Coolant Tank (Sht 2, A3)

LT1, LT2 Indicator, Neon, 250V, AC Volts Present (Sht 1, C3)

M1

Motor, Pump, ½ hp 230VAC, 50/60 Hz, 1Ph (Sht 2, C2)

MC1 Relay, 120 VAC, Inrush, Coil (Sht 2, B9), Contact (Sht2, A1)

MC3 Relay, 120 VAC, Pump Motor Control

(Coil at Sht 2, A7) (Contacts at Sht 2, C2)

PS1

Pressure Switch, Plasma Gas, N.O. , 51 PSI (Sht 2, C9)

R1 Current Control 10K (sht 2, D9)

R2 Inrush, 4.7 ohm 30W (Sht2, A1)

SA1, 2

Snubber, Contactor & Relay coil (Sht 2, A7)

SG1

Spark Gap (Sht 1, A9)

SOL1

Solenoid, Plasma Gas, 24 VAC (Sht 2, D9)

SOL2

Solenoid, Shield Gas, 24 VAC (Sht 2, D9)

SOL3

Solenoid, H2O Mist (water shield), 24 VAC (Sht 2, D10)

SW1

Switch, RUN / SET, DPDT (Sht 2, D10)

SW2

Switch, Shield Mode, SPDT (Sht 2, D10)

SW3 Switch, Gas Mode, SPST, rear panel (Sht 2, B2)

T1

Aux Transformer (Sht 2, B2)

T2

Transformer, HV, 120/6000V (Sht 1, A9)

TB4

Terminal Block (Sht 1, C9)

TS1

Temperature Sensor, NTC, Coolant Return (Sht 2, A5)

TS2

Temperature Sensor, NTC, Ambient (Sht 2, A5)

W1

Contactor , Input (Coil at Sht 2, A8) (Contacts at Sht 1, B2)

IM #2 Section A (lower)

ELECTRODE (-)

WORK (+)

1 READY +

2 READY -

3 INVERTER_FLT +

4 INVERTER_FLT -

5 OVERTEMP_FLT +

6 OVERTEMP_FLT -

7 PWR_PRESENT +

8 PWR_PRESENT -

9 OUT_COM (+3 to 5VDC)

10 VAC_SELA

11 VAC_SELB

12 IS_IDA

13 IS_IDB

14 IS_IDC

15 ENABLE +

16 ENABLE -

17 START2 +

18 START2 -

19 SPARE

20 SYNC_IN +

21 SYNC_IN -

22 NC

23 NC

24 47 OHM to COMM

25 DEMAND +

26 DEMAND -

27 47 OHM to COMM

28 CURRENT +

29 CURRENT -

30 47 OHM to COMM

1 COMMON

2 /1TORCH START *

3 NA

4 /1TORCH GAS SOL ON *

5 /MAIN TORCH IDLE *

6 /1TORCH PRESS OK *

7 FLOW SENSOR (pulses)

8 LOW COOLANT FLOW

9 COOLANT LEVEL OK

10 COMMON

11 NA

12 /PLASMA ENABLE-HMI

13 /COOLANT PUMP ON

14 COMMON

15 /PILOT ENABLE

16 /RAS ON

17 /CONTACTORS ON

18 COMMON

19 /COOLANT FANS ON

20 /1TORCH CONTACTOR ON *

* Used with 1 Torch Option

21 /PLASMA ENABLE RELAY

22 COMMON

23 PILOT CURRENT SIG-

24 NC

25 PILOT CURRENT SIG+

26 COMMON

27 WORK CURRENT SIG-

28 WORK CURRENT SIG+

29 NC

30 AMBIENT TEMP

31 COOLANT TEMP

32 COMMON

33 -15 VDC

34 COMMON

35 24 VDC

36 COMMON

37 24 VDC

38 COMMON

39 24 VDC

40 COMMON

RIBBON CABLE 40 ckt CCM (J23 (Sht 2, C7)) - RELAY PCB (J4 (Sht 2, B7))

1,3,5,7

24 VDC

2,4,6,8

COMMON

9,10 NC

11-16

SERIAL DATA

RIBBON CABLE 30 ckt.

CCM (J31-33) - INVERTER (J100)

(Sht 2, C4) (Sht 1, A6, B6)

1,2

24 VDC

3,4,7,10 COMMON

5 PILOT ENABLE +

6 PILOT ENABLE –

8 PILOT CURRENT SIG –

9 PILOT CURRENT SIG +

RIBBON CABLE 10 ckt

RELAY PCB (J3 (Sht 2, A6)) -

PILOT PCB (J42 (Sht 1, C8))

RIBBON CABLE 16 ckt

CCM ( J37 (Sht 2, C8)) -

DISPLAY PCB (J17 (Sht 2, C9))

D3, RED, CAP

IMBALANCE

D4, GREEN, READY

D6, GREEN, -12V

D11, GREEN, +12VP

D13, GREEN, +12V

D1, RED, INV FLT

D14, RED, OVER TEMP

D24, GREEN, PWM ON

D32, RED, PRI OC

LEDS

D3, RED, MISSING PHASE

D4, RED, AC V HIGH

D14, RED, AC V LOW

D26, GREEN, +12V PRI

D30, GREEN, 24VDC

D44, GREEN, T1 ON

AC

SUPPRESSION

PCB

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J50

AC LINE

GND

1

2

3

4

J52

INTERNAL AC INDICATOR

1

2

3

4

J51

PANEL AC INDICATOR

LT1

LT2

019X504000

(3)

(2)

(1)

(10)

(11)

(12)

(13)

CHASSIS GND

Wire #48 from J61-1 to:

J61-2 for 208-230 VAC

J61-3 for 400 VAC

J61-4 for 480 VAC

2

1

0

2

/

1

3

/

8

T

A

D

1

0

Added MC3 Pump Control

LT1 & LT2

INPUT POWER

NEON INDICATORS

Rear Panel & Internal

1

2

3

4

5

6

7

TB4

WORK (+)

019x502000

019x502700

019x502000

TEST POINTS

TP1 SECONDARY GND

TP2 24VDC

TP3 DC INPUT POSITIVE

TP4 VCC1

TP5 VCC2

TP6 GATE

TP7 PRIMARY GND

TP8 +12V PRIMARY

TP9 P ISOL GND

CONTROL PCB LEDS

CAP BIAS PCB LEDS

MAIN PCB LEDS

Component Locations (not including PCB components)

230V 400V 480V ERR

/VAC_IDAb 0 1 0 1

/VAC_IDBb 0 0 1 1

Measure relative to TP1 (24VDC_RET)

"0" = 10-12V "1" = 24V

CB1

ON / OFF

(27

A

&

B

)

(26

)

(28

)

(27B)

8A, 500V, SB

F2

8A, 500V, SB

F1

(27A)

(86A)

(86B)

(85A)

(85B)

3

1

0

2

/

6

1

/

1

T

A

D

2

0

Added R1, K1, MC1 inrush

1

2

IN1

1

2

IN2

1

2

IN3

1

2

OUT1

1

2

OUT2

1

2

OUT3

GND2B

EMI

FIL-

TER

PCB

1

2

IN1

1

2

IN2

1

2

IN3

1

2

OUT1

1

2

OUT2

1

2

OUT3

GND2B

EMI

FIL-

TER

PCB

L6

Toriod Core

L5

Toriod Core

L4

Toriod Core

CHASSIS GND

CHASSIS GND

(20)

(21)

(22)

(1

-2

0)

(2

-2

1)

(3

-2

2)

(1-20

)

(2-21

)

(3-22

)

L3

Toriod Core

(7)

(8)

(9)

1

2

J41

TIP

1

J44

PILOT PCB

019X501600

1

PILOT

CHASSIS GND

(52)

CHASSIS GND

(49)

1

L1

1

L2

1

L3

1

Earth

380-415

VAC

INPUT

(Customer

supplied

power cord

must pass

through

ferrite core

assembly.)

(3)

(2)

(1)

CHASSIS GND

(3)

(2)

(1)

(55

)

(55)

(53)

(51A)

(49)

03 Misc updates & corrections

DAT

6/27/2013

o
b
g
w

More updates & corrections

3

1

0

2

/

2

1

/

9

T

A

D

4

0

J58A

J58C

J58B

PILOT BOARD LED'S

D2 PILOT ENABLE

D11 +5V

TEST POINTS

TP1 GND

TP2 PILOT GATE

TP3 +5V

Art # A-11944_AB

Art # A-11944_AB

Advertising