Auto-cut 200 xt, Cnc connections – Tweco 200 XT Auto-Cut 400V User Manual

Page 90

Advertising
background image

AUTO-CUT 200 XT

A-8

APPENDIX

Manual 0-5284

CNC Connections

Start Motion

(OK-To-Move)

Cutting Machine

CNC Cable

Power Supply

Shield

J15

1

3

4

9

6

7

8

13

14

12

5

OK-To-Move

2

(1)

3

4

9

6

7

14

12

5

2

START/STOP

*

( )

( )

( )

( )

( )

( )

( )

( )

( )

{

*

*

NC

..........

Source, 16 VDC, 10 ma.

... Divided Arc V (-)

..........

..........

..........

Pre Flow ON (+)

Pre Flow ON (-)

10

11

10

11

( )

( )

..........

Divided Arc V (+)

Corner Current Reduction (-)

Corner Current Reduction (+)

...

Relay

DCV (-)

Contact or

(1A @

DCV (+)

120 VAC ( 15 - 18 VDC @

or 28 VDC) up to 100 ma.)

* Power Supply Gnd not used for CNC cable

Do not connect wire #1 to anything.

** Cable Shield drain wire must be

connected to ground at cutting machine.

**

Corner

Art # A-11502

SW6

DC

(+)