CCM Status Code

Group 3 -- Gas Controller Status & Protocol

Code

Message

Remedy / Comments

301

Not used

Reserved for other models.

302

Reserved

No information available; Contact customer service

303

Gas Supply Pressure

out of range.

Autocut is in SET mode or Plasma gas pressure is too low; Defective gas pressure sensor

(PS1).

304

Gas Control Purging

Normal following power up or returning from Plasma Disable.

305

Not used

Reserved for other models.

306

Not used

Reserved for other future use.

307

Not used

Reserved for other models.

308

Gas Control Type

Mismatch

Wrong CCM, must be Auto-cut type.

309

Not used

Reserved for other models.

310

Not used

Reserved for other models.

311

Not used

Reserved for other models.

312

Not used

Reserved for other models.

313

Not used

Reserved for other models.

CCM Status Code

Group 4 -- Torch Coolant System

Code

Message

Remedy / Comments

401

Coolant Level low

Check coolant level, add as needed.

402

Low coolant flow

Coolant flow as measured by flow switch FS1 is less than 0.7 gpm; Clogged filter;

Restriction in torch lead or head; Wrong style consumables; broken or defective torch

coolant tube/check valve; Defective pump or bypass valve.

403

Coolant overheated

Coolant supply temperature exceeded 75 degrees Celcius (167F). Operating with either

lower side panel loose or removed; Coolant fan failed; radiator fins clogged with dirt.

404

Coolant System not

ready.

Proper coolant flow of 0.7 gpm as measured by flow switch FS1 was not obtained dur-

ing up to 4 minutes of Priming. New installation can require additional Priming cycle(s)

to fill hoses with coolant; cylce power to restart Priming; Coolant hoses or torch hoses

reversed; Clogged coolant filter; Restriction in torch lead or head; Wrong style consum-

ables; broken or defective torch coolant tube/check valve; Defective pump or bypass

valve.

405

Low Coolant Level

Warning

Low coolant level during cut, does not stop cut.

Add coolant as required.

406

Not used

Reserved for other models.

407

Coolant overheated, high

ambient.

Ambient greater than 40 deg C results in coolant overheating. Reduce cutting duty cycle;

Reduce ambient; Add separate cooler.

NOTE

There are no 500 codes