2.05 Power Supply Specifications & Electrical Requirements

Auto-Cut 200 XT™Power Supply Specifications

Max OCV (U0)

425 vdc

Max Output Current

200 Amps

Output Voltage

60 - 170 vdc

Duty Cycle Rating

100% @ 200A @ 200V (40 kW)

Operating range

14°F to 122°F (-10°C to + 50°C)

Power Factor

0.94 @ 200 ADC Output

Cooling

Forced Air (Class F) and Liquid Cooled

Auto-Cut 200 XT™Power Supply

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

400

50/60

41

60

100

#6

16

* Suggested wire size based on United States NFPA 70 National Electrical Code 2011
edition published by the National Fire Prevention Association. Listings are from table
400.5(A)(2) for flexible cord of certain types rated for 75 deg C in ambient tempera-
tures up to 30 deg C. Using wires of lower temperature rating or different insulation
type may require larger wire size. Derate for higher ambient.
These are suggestions only. Always refer to your local and national codes that apply to
your region for final determination of correct wire type and size.

CAUTION

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.