TB2

Function

Connection

Hold Start

TB2-2 (+),TB2-1 (-) (comm. )

Preflow ON

TB2-4 (+), TB2-3 (-) (comm.)

Pilot is ON (contacts)

TB2-6, TB2-8 rated 1A @ 120 VAC or 28 VDC

OK to Move (contacts or DC Volts)5 TB2-12 (+), TB2-10 (-)

TB3

Function

Connection

Plasma Marking

TB3-2(+), TB3-1(-) (comm.)

Corner Current Reduction

TB-4(+), TB3-3(-)(comm.)

Cut Expanded Metal

TB3-6(+), TB3-5(-)(comm.)

Spare NO Contact

TB3-7, TB3-8

Spare NC Contact

TB3-9, TB3-10

Spare NO Contact

TB3-11, TB3-12

CNC Input / Output Descriptions

All inputs except the Analog Current Control are digital active low (contact or SW closure).

CNC Enable / Disable ( input)

— Requires closed connection rated for 10 ma. @ 20VDC for unit to operate.

Factory installed jumper between TB1-1&2 must be removing when connecting user supplied Enable/Disable circuit.
4 Start/Stop (input)—Switch (momentary or sustained) rating 35ma. @ 20 VDC

Start / Stop circuit configuration. Momentary Start / Stop (Latched) is only available at TB1.

MOMENTARY START / STOP

START / STOP

TB1-6

TB1-5

TB1-4

SUSTAINED START / STOP

START

STOP

TB1-5

TB1-6