AUTO-CUT 200 XT
Manual 0-5284
APPENDIX
A-3
TB2
Function
Connection
Hold Start
TB2-2 (+),TB2-1 (-) (comm. )
Preflow ON
TB2-4 (+), TB2-3 (-) (comm.)
Pilot is ON (contacts)
TB2-6, TB2-8 rated 1A @ 120 VAC or 28 VDC
OK to Move (contacts or DC Volts)5 TB2-12 (+), TB2-10 (-)
TB3
Function
Connection
Plasma Marking
TB3-2(+), TB3-1(-) (comm.)
Corner Current Reduction
TB-4(+), TB3-3(-)(comm.)
Cut Expanded Metal
TB3-6(+), TB3-5(-)(comm.)
Spare NO Contact
TB3-7, TB3-8
Spare NC Contact
TB3-9, TB3-10
Spare NO Contact
TB3-11, TB3-12
CNC Input / Output Descriptions
All inputs except the Analog Current Control are digital active low (contact or SW closure).
CNC Enable / Disable ( input)
— Requires closed connection rated for 10 ma. @ 20VDC for unit to operate.
Factory installed jumper between TB1-1&2 must be removing when connecting user supplied Enable/Disable circuit.
4 Start/Stop (input)—Switch (momentary or sustained) rating 35ma. @ 20 VDC
Start / Stop circuit configuration. Momentary Start / Stop (Latched) is only available at TB1.
MOMENTARY START / STOP
START / STOP
TB1-6
TB1-5
TB1-4
SUSTAINED START / STOP
START
STOP
TB1-5
TB1-6