5. Slide the positioning tube down to the torch head. Hold the torch head stationary. Rotate the positioning

tube onto the torch head. Pull the leads back as needed to ensure a proper fit through the Mounting Tube.

Do not let the torch leads twist.

CAUTION

Ensure that the leads do not twist within the mounting tube. Leads must lie as shown in the installation sketch.

6. The lower end of the Mounting Tube includes four threaded holes. Install an Allen set screw from the hard-

ware kit in any of the threaded holes to secure the Torch Head Assembly to the Mounting Tube.

7. Fasten the positioning tube into the mounting block. Slide the leads end cap down onto the torch position-

ing tube. Ensure that the end cap engages the O-ring at the top of the positioning tube.

8. Install the shield cup, and cartridge assembly (including consumables) onto the torch head.

3.13 Install Consumable Torch Parts

1. Refer to the Torch Speed Charts to select the correct parts for the application. The application will determine

which torch parts must be used. Refer to the speed charts for the proper torch parts to install for a selected

application.

CAUTION

Do not interchange parts. Make sure both the tip and electrode in the torch correspond with the plasma and shield
gas in use for the application.

2. Install the consumable parts as follows to ensure proper operation. These steps will help ensure that parts

are seated correctly.

NOTE

For 200-Amp consumables, when replacing the shield retainer or the shield cup, assemble these two parts first before
assembling the other consumables.

Shield

Retainer

Shield Cup

Shield Cap Shield Gas

Distributor

Tip

Plasma Gas

Distributor

Electrode

Cartridge

Art # A-08303

A

B

C

1 - Assemble “A” 200 A only.

2 - Assemble “B”.

3 - Assemble “B” to “C”.

4 - Assemble “A” to “B-C” assembly.

3. Stack the consumable parts together.

4. Insert the stack of consumable parts into the cartridge. Ensure that the large O-ring on the torch tip fits

completely into the cartridge. If any part of the O-ring protrudes from the cartridge, the parts are not seated

properly.

Advertising