3.08 Connect Gas Supply Lines

1. Connect the gas supply lines to the appropriate input ports shown below. The first view shows factory

default for using shop air. All other gasses to use the second view, bypassing the two stage air filter.

NOTE

When using shop air, connection must be made through the two stage air filter located in the center of the rear panel.

Do not use the two stage air filter for other gases.

Art # A-11952

Torch Leads Port

Work Cable Port

Optional Water
Mist Port

Shield Gas Port

Plasma Gas Port

Torch Leads
Ground Terminal

J15 - CNC

CB4 - 5A 120 VAC

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

USER INPUT

HEIGHT CONTROL

AIR / O2

PLASMA

N2 / H35

PLASMA

IN OUT

Shop Air Input

Factory Default Air/Air Using Shop Air

Art # A-11953

Torch Leads Port

Work Cable Port

Optional Water
Mist Port

Shield Gas Port

Plasma Gas Port

Torch Leads
Ground Terminal

J15 - CNC

CB4 - 5A 120 VAC

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

USER INPUT

HEIGHT CONTROL

AIR / O2

PLASMA

N2 / H35

PLASMA

All Gases Except Air

Advertising